My boiler manual recommends a temp setting of 200 degrees for baseboards and convectors. SharkBite fittings can be used for hydronic heating applications if the temperature does not exceed 200F.NOTE: Glycol mixture for hydronic is acceptable up to and including 100%. A SharkBite fitting contains a rubber O-ring, which is not best for permanent connections. I also think its extra-wise to have some kind of instrumentation about floods going on. What kind of pipe did you use. In Stock. Water systems should not be allowed to freeze. Coil Oxygen Barrier Radiant Heating PEX Pipe is used for hydronic heating applications. Happy I asked. PEX Tubing Technical Specifications - PexUniverse I will be recovering the pipe with concrete when the leak is repaired. How can you tell the difference between PEX-A and PEX-B? Some of these include: It has superior characteristics: elastic and thermal memory. Use Pex-Al-Pex instead..it's aluminum sheath will keep the pipe in shape, and it has about the same expansion characteristics as copper. SharkBite 1/2 in. Simply insert the pipe and the teeth bite down and grip tight, while a specially formulated O-ring compresses to . Today I'm telling you why I don't use Sharkbites and why I don't let my plumbers use them either. This is a true story but is a single occurrence, I dont really know how likely this is to happen more. Designed for years of trouble-free service and backed by a 25-year limited warranty*. AquaLock Push-to-Connect Fittings Made of high-performance lead-free** brass or thermoplastic material, AquaLock push-to-connect fittings give you fast and secure connections without any tools. PEX pipe cant be heated or exposed to a direct flame. What types of pipe can SharkBite fittings be used with? You'll also need the correct fittings to interface the PEX to the baseboard. What types of pipe can SharkBite fittings be used with? Can I use SharkBite fittings on baseboard heat? It has little teeth in it that are supposed to grab the copper pipe and hold on. So if youre using them for compressed air, make sure the pressure is not too high. PEX pipe is flexible and can be navigated around obstacles. I've looked at electric soldering a couple times for the same reasons. SharkBite Water Heater Connector allows you to easily connect your Hot and Cold-Water Supply lines to your Water Heater.. How To Install New Baseboard Heating Element Using Shark Bite Fittings SharkBite fittings are certified to 200 PSI and 200F (93C). The last thing you want is for your fitting to blow out under high pressure! How soon after installation can you pressure test PEX tubing? Over-bending the PEX pipe, deforms its' round shape, restricts flow and over-stresses the pipe. Press J to jump to the feed. Can you use PEX pipe for hot water baseboard heat? If it wasnt clean and smooth when it was originally inserted into the sharkbite fitting it might have been hard for the oring to seal or the teeth to seat properly, which may have in turn been the cause of failure. This worried me so I put expansion loops in the heating lines (literally just looped and clipped a several foot diameter loop of PEX in the middle of the run to allow for expansion and contraction) but i have found they're not needed, at least for the application I have. Can I use PEX pipe for compressed air applications? and Push (sharkbite) but that one has already bee defunked. Although you can use SharkBite fittings in inaccessible places, most plumbers recommend you use . If you want good clean oats, you'll have to pay a fair price. SharkBite fittings canleak due to one of thesereasons: Review installation instructions to ensure you've followed the correct steps. Add to Wish List. So it was loose and had the same problem. SharkBite PEX Barb fittings are compatible for potable water distribution and hydronic heating applications. But clearly, it did not. Remember, however, that they only work with copper, PEX, and CPVC pipes. The tube support liner can drop out of the fittings as it can move freely past the grab ring. Your email address will not be published. Browse our brass push products. Unroll about 6 in to 8 in. PEX pipe can be pressurized for testing as soon as all necessary connections have been made. Parallel runs of pipe can be spaced as close as necessary. PEX can withstand high temperatures and pressures. I think their heat rating is dependent on pressure as well as the material they are joining. According to sharkbite website they are rated for hydro nic applications and are rated for pressure up to 200 psi and 180-200 F. SharkBite fittings can only be used with hard drawn copper types K, L, and M. Yes. FLOOD ALERT. AquaLock - Watts Can you use PEX pipe for hot water baseboard heat? My story is a single occurrence. What is the pipe insertion depth for the SharkBite fittings? Can PEX be used for baseboard heating? If I remember correctly sharkbites are rated at 240 deg. PEX Plumbing Disadvantages: What You Need to Know My goal is to use sharkbite where possible because I have heard it used for plumbing, I just wasn't 100% sure about heating. It is not required for copper or CPVC, however, it is not necessary to remove the tube liner from the fitting. Where is PEX pipe approved for plumbing use? SharkBite fittings are certified for use underground, in behind the wall applications, and as a manufactured joint without access panels. A SharkBite connector with 1/2 copper pipe inserted. Froling 40/50 ,150 gal.buffer tank,1000 gal. It is flexible, resistant to scale and chlorine. Picture 6: Sharbite Fittings example of how installed. Yes. What should I do if a SharkBite system is leaking upon installation? Do I need the Disconnect Clip to remove a SharkBite fitting? SharkBite PEX barb fittings are compatible for potable water distribution and hydronic heating applications. It can also be used in domestic water applications because it meets the NSF/ANSI/CAN 61 standard. Push-fit fittings are ideal for appliances that use potable water, plumbing, water heaters, and hydronic heating systems. My heating system is boiler + hot water with baseboard fins and copper pipes. Why do plumbers not like SharkBite fittings? Perhaps not but just an observation. PEX is a great option for compressed air applications. Extending Baseboard heat using PEX back to copper The Types of PEX (PEX-A, PEX-B, PEX-C, PEX-Al-PEX) - SupplyHouse.com As a follow up did you use sharkbite for your pex or soldered connections. Flexibility PEX-A is the most flexible, allowing for it to be fastened by cold expansion, which allows the end to be fluted prior to inserting the fitting. No, PEX pipe is not intended for compressed air applications. AquaLock Push-to-Connect Fittings - Watts I wonder why that thing is going off?. The SharkBite 1/2 inch x 3/8 inch Compression Angle Stop Valve was designed to be an industry standard, trusted by plumbers across the globe. You don't need any specialized toolsto connect SharkBite fittings. There is no need to solder or glue these fittings, and they can be used with both copper and plastic piping. PEX is short for cross-linked polyethylene. It has developed a leak and I was wondering if it is better to use Pex or stick with the copper. PEX pipe doesnt corrode or develop pinholes. Nice. Gray PEX pipe, like white, can be used for either hot or cold water (although not all DIY centers carry gray). Sign in or register to get started. It is recommended to solder any joints prior to installing a SharkBite fitting. They will not work with PVC or other types of piping. It is important to use a pipe that is rated for the pressure of your compressor, as using a lower-rated pipe could result in leaks or even bursting. In another post I was reading that the overheat loop can get as hot as 210 F. That's above the rating for sharkbite fittings, so I'll stick with solder until well away from the boiler. I did this for two reasons: after consulting the product guides for the particular brand of PEX I used with an oxygen barrier it did not say crimp rings were approved for use and because sharkbites are full-port whereas most PEX connections go inside the tube, which is already smaller diameter than their copper nominally-sized counterparts. You could also use the Sharbite Ball valves in this example. The rule of thumb has been to come off the boiler 10 feet with copper or iron before changing to PEX. Find many great new & used options and get the best deals for SHARK BITE 25482Z 4-PORT HYDRONIC HEATING MANIFOLD 1" SWT X 1/2" PEX at the best online prices at eBay! I've got one on a hot water line and no leaks. 1. Good morning, Yes. Will SharkBite fittings work on polybutylene pipe? SharkBite 3/4 in. x 100 ft. Coil Oxygen Barrier Radiant Heating PEX-C The kit features a 6-loop SharkBite radiant manifold, a Cash Acme TMV, SharkBite oxygen barrier PEX and fittings, thermostat, and a circulating pump with an integrated relay. SharkBite push-to-connect fittings are certified for use within a concealed wall, but consulting with local plumbing codes is recommended for specific applications. | Q:Can I use sharkbite fittings to install hot water heater baseboards as long as I use the oxygen barrier pex. Supposed to install tomorrow so any input tonight would be great. Installation is fast and easy on almost any CTS-sized pipereducing the risk of installation errors and leaks. They are more expensive than typlical copper fittings, but they are easy to install and can removed for other use. Push-to-Connect Fittings FAQs | SharkBite However, soldering is generally considered to be the stronger option. Sharkbite may be fine in 30 years, but it may not be, too.