The following items can be purchased separately as accessories or replacement items for your 7305 Series DeVilbiss Suction Unit: NOTE The use of electrical cables and accessories other than those specified in this manual or referenced documents may result in increased electromagnetic emissions from the product or decreased electromagnetic immunity of the product. Between patients: The compressor portion of the DeVilbiss Suction Unit 7305P & 7305D Series (excluding internal rechargeable batteries) is warranted to be free from defective workmanship and materials for a period of two years from date of purchase. Remove bacteria filter, 4-3/8 tubing, and connection elbow and set aside. Spot publicitaires, documentaires, films, programmes tl et diffusion internet, Cours de franais/anglais des fins professionnels, prparation aux examens du TOEFL, TOEIC et IELTS, Relve de la garde royale Buckingham Palace, innovation technologique et apprentissage rapide. © 2002 - 2022 HealthProductsForYou.com. Disposable Collection Container with Internal Filter Cartridge, Disposable Collection Container with External Bacteria Filter, Reusable Collection Container with External Bacteria Filter, DEVILBISS GUIDANCE AND MANUFACTURERS DECLARATION. Opening or tampering with the unit will void warranty. A different brand maybe shipped if ordered brand is unavailable but general specs will be maintained. Interference may occur in the vicinity of equipment containing a transmitter. Contact your local authorities for instruction on proper disposal.NOTE Do not connect the AC adapter to an outlet controlled by a switch to ensure power is supplied to unit at all times.NOTE Do not connect the DC power cord to an outlet that is not constantly energized. Note - Do not substitute any other material for this bacteria filter. 3. For all medical applications: The 7305 series is equipped with a switch mode power supply allowing operation on any AC voltage (100-240 VAC, 50/60 Hz). It meets the American Association for Respiratory Care (AARC) guidelines for neonatal, infant, child and adult homecare suctioning. Operation time will decrease with higher vacuum levels.NOTE When charging the battery, use an external power source and verify that the charge light illuminates when the unit is in the Off position. Electric shock hazard. Check electrical connections during charging. Where P is the maximum power rating in watts and D is the recommended. Medical professionals, medical facility employees 855.571.2100, Need help with SupplyManager?800.422.0280, Consumers: Please visit SimplyMedical.com, Some Units might require charging before first use, Adjustable flow regulator allows for vacuum of 80 to 550 mm HG and free flow of 27 lpm, Unit meets the RTCA/DO160D Aircraft Standard, Increased Battery Capabilities of up to one hour, 1,200 mL reusable canister available separately, Electrical Requirements 100-240 VAC, 50/60 Hz, 0.75 A, Aspirator comes with suction tubing and metal base, Aspirator comes with 1 suction tube with filter, 4 legs (no base), Regulator gauge encased in base for protection and longer service life, Molded plastic base is durable and easy to clean, Comes with suction tubing kit and 3 filters. DUNS # 968090816. Replacement Biomedical Battery for Devilbiss Health Care Inc 7305 Series Homecare Suction Unit. Field strengths from fixed transmitters, as determined by an electromagnetic site survey, should be less than the compliance levels (V1 and E1). Do not remove filter media from filter cartridge. 1. Dallas, TX 75243. Internal rechargeable batteries are warranted for 90 days. Close supervision is necessary when this product is used by, on, or near children or physically incapacitated individuals. This device is intended for use in the electromagnetic environment specified below. Suction at the patient is automatically obstructed when liquid level reaches the float shut-off located on the underside of the container lid.NOTE Always transport unit with vacuum regulator knob rotated fully clockwise in case unit is dropped.CAUTION When automatic float shut-off is activated, contents of the container should be emptied. Drive DeVilbiss Healthcare 7305D-D Suction Unit, 800cc Disposablebottle, tubing, elbow, and AC and DC power cords (does not include carry case) (Surcharge May Apply). The bacteria filter should then be connected to the 90 elbow connection, and the 90 connection should be connected to the top of the container lid where it says
Remove filter by disconnecting it from suction unit and lid assembly.
Keep the outer surface of the tubing clean by wiping with a clean, damp cloth. NOTE Your DeVilbiss Suction Unit contains no user-serviceable parts. If you have any questions or comments, please send them to our address on the back cover.For Service Call Your Authorized DeVilbiss Healthcare Provider: Medical Electrical Equipment needs special precautions regarding Electromagnetic Compatibility (EMC) and needs to be installed and put into service according to the EMC information provided in the accompanying documents.Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment.The equipment or system should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the configuration in which it will be used.NOTE The EMC tables and other guidelines provide information to the customer or user that is essential in determining the suitability of the Equipment or System for the Electromagnetic Environment of use, and in managing the Electromagnetic Environment of use to permit the Equipment or System to perform its intended use without disturbing other Equipment and Systems or non-medical electrical equipment. The filter cartridge must then be replaced. We want you to be a satisfied customer. The use of this website is subject to our shopping terms des professionnels de la langue votre service, Cest la rentre TransProfessionals, rejoignez-nous ds prsent et dbuter les cours de langue anglaise et franaise, + de 3000 traducteurs, + de 100 combinaisons linguistiques, Because of the small size, lightweight, and DC operation, it is ideal for providing suction at home or on the go with the DC cord. Your email address will not be published. Easy-to-Read Gauge -The unit has a conveniently placed gauge for easy reading. Remove filter cartridge and 43/8 tubing. Rinse with clean, warm water and air dry. The gauge located on the top of the unit near the handle will allow you to select a specific level of vacuum. Texas HUB # 1275470693000. Comment document.getElementById("comment").setAttribute("id","a0805468458f68b3599170abb4ddf727");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Read all instructions before using. Copyright 2022 TransProfessionals. On 7305D series, the units are not factory equipped with a rechargeable battery; check with your equipment provider to determine if your unit has been upgraded with a rechargeable battery. Important If battery recharge is delayed beyond 6 months, battery may be able to provide full run time after completion of 3 full charge and discharge cycles.NOTE A fully charged battery will provide approximately 60 minutes of continuous operation at a zero vacuum level (free flow). Do not place in or drop into water or other liquid. Plug the AC end into a grounded wall-outlet power source.NOTE The power supply may become warm to the touch during charging or running of the unit. Wipe the case using a clean cloth dampened with detergent and/or disinfectant. To ensure proper operation from internal battery, fully charge the battery for 17 hours as explained in the Battery Charging section. Do not reverse direction of filter. Use vacuum adjustment knob to increase vacuum level.
Check tubing connections for breaks or leaks. CAGE Code 6H2R8. When using electrical products, especially when children are present, basic safety precautions should always be followed. This device is suitable for use in all establishments including domestic, and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Compact Design - High-performance capabilities are conveniently placed in a small compact package weighing less than 6.3 lbs. Dispose of all accessory components that are not suitable for reuse, i.e., collection container, filter, tubing and carrying case. Portable and mobile RF communications equipment should be separated from the device by no less than the recommended separation distances calculated/listed below: For transmitters rated at a maximum output power not listed above, the recommended separation distance D in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Remove filter cartridge and 4-3/8 tubing and set aside. Check that all tubing is connected properly. Wipe the housing with a clean cloth and a commercial (bacterial-germicidal) disinfectant that meets the requirements listed in the NOTE below and is used as per the disinfectant manufacturers recommended dilution rates and instructions. This Sealed Lead Acid battery has a nominal voltage of Chemistry:Rechargeable VRLANominal Voltage:12vNominal Capacity:2.5AhDevice Manufacturer:Devilbiss Health Care IncApplication:7305 Series Homecare Suct OSI Batteries is an authorized factory-direct distributor with custom production capabilities, delivering professional battery solutions worldwide. Any defective part(s) will be repaired or replaced at DeVilbiss Healthcares option if the unit has not been tampered with or used improperly during that period. DeVilbiss Vacu-Aide 7305 Series Homecare Suction Unit is a compact medical suctioning device designed for reliable, portable operation. Switch to another power source immediately after the low battery light appears to avoid an interrupted suction procedure. Wipe the housing with a clean cloth and any commercial (bacterial-germicidal) disinfectant. The customer or user of this device should assure that it is used in such an environment. This increased demand has caused shortages for some products. Reconditioning must only be carried out by the manufacturer or service provider. We have secured 500 cases of Halyard ASTM Level 3 Masks with Wraparound Visor and we are inviting pr If the user of this device requires continued operation during power mains interruptions, it is recommended that the device be powered from an uninterruptible power supply or battery. 1. En 10 ans, nous avons su nous imposer en tant que leader dans notre industrie et rpondre aux attentes de nos clients. Suite 119 Mains power quality should be that of a typical commercial or hospital environment. The power indicator light displayed on the top of the unit will indicate which power source is being used by staying continuously lit when external power is connected. Illuminated when external power is supplied.L2 Yellow Battery is being charged. THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. AC to DC Adapter (not shown)DC power cord (not shown) optionalInternal rechargeable battery (not shown) 7305P series onlyCarrying case (not shown) 7305P series only, DC power cord (not shown) optionalInternal rechargeable battery (not shown) 7305P series onlyCarrying case (not shown) 7305P series only. Keep the power cord away from heated surfaces. The DeVilbiss 7305 Series Drive DeVilbiss Healthcare 7305D-D-EXF Suction Unit, 800cc Disposable container with external Filter, tubing, elbow, and AC and DC power cords (Surcharge May Apply). Visually inspect unit for any damage, missing parts, Use an independent vacuum gauge to verify the unit provides the proper vacuum level as stated in, Discard and replace collection container, filter, and tubing between, Wipe the surface using a clean cloth dampened with. used as medical advice, to diagnose, or treat patients. L1- Green External power supplied to unit from AC power source or DC cord. The disposable collection container and lid are meant for single-patient use.
Do not operate the unit more than a few minutes if the low battery indicator light is lit. Change filter cartridge if overflow occurs or every two months, whichever comes first. Sign up for exclusive discount offers & promotional coupons! To prevent possible risk of infection from contaminated cleaning/disinfection solutions, always prepare fresh solution for each cleaning cycle and discard solution after each use. and privacy policy. DUNS # 968090816. Light will go out when battery is fully charged. Replace with a clean DeVilbiss bacteria filter (non-sterile) and remount to suction unit and lid. divers domaines de spcialisations. The fluids are trapped in the collection bottle for proper disposal. Shut off unit using power switch and allow vacuum to Disconnect power source from the DC input receptacle on the unit.
Drive DeVilbiss Healthcare 7305D-633 Int Filter, Disposable Container Comp Kit Assembled (Surcharge May Apply). The DeVilbiss 7305 Series Vacu-Aide Suction Unit meets Drive DeVilbiss Healthcare 7314P-D Vacu-Aide Assembled Quiet Suction Unit with Battery, NAM (Surcharge May Apply). Homecare Suction Unit has automatic float shut-off to prevent overflow into the unit. Wash jar, lid, o-ring, and overflow valve in a solution of warm water with a mild, liquid detergent (e.g. With Disposable Container and External Bacteria Filter, With Reusable Container and External Bacteria Filter, Disposable Container with Internal Filter Cartridge and Splash Guard, Disposable Container with External Bacteria Filter, Reusable Container with External Bacteria Filter, Disposable Container w/Internal Filter Cartridge & Splash Guard, Disposable Container or Reusable Container with External Bacteria Filter, HOW TO OPERATE YOUR 7305 SERIES DEVILBISS SUCTION UNIT.