When a sprinkler fitter apprentice can demonstrate competence in vital skills, the apprenticeship will be complete. Upon successful completion of this module, the trainee will be able to describe the opportunities in the construction businesses and how to enter the construction workforce; explain the importance of critical thinking and how to solve problems (potential barriers, problems related to planning and scheduling); and explain the importance of good social skills and identify the way they are applied in the construction trade (resolving conflict with co-workers and supervisors, give and receive constructive criticism, social issues within the workplace, working in a team environment, being an effective leader). Wil jij meewerken aan de veiligheid van mensen en gebouwen? On the Job Training Hours: 8000 AFSA is the voice of the merit shop fire sprinkler contractor. For other questions, please contact the JAC directly at (562) 907-7622. See the stories of Fire Sprinkler Fitters who were organized, The skilled members of Local 550 have been installing these, The Sprinkler Fitters of Local 550 in the Greater Boston area, 2022 All Rights Reserved, UA Local 550 | Developed by. Email:bt821@msn.com.
Excellent pay, benefits and job security. Years to Complete: 4-5 HCC Campus: Dale Mabry and Plant City. Upon completion of this module, the trainee will be able to identify types and properties of soil, explain excavation safety, explain sloping requirements for different types of soil, explain digging trenches, describe excavation support systems, describe types of bedding material, identify and describe types of underground pipe, describe thrust blocks and restraints, identify and describe hydrants, yard valves, hydrant houses, and associated appurtenances, explain testing, inspection, and chlorinating of underground pipe, and fill out an Underground Test Certificate.
Responsibilities include unloading and installing allpiping and tubing apparatus and equipment such as:, The technologies in this industry also include CO2, Cardox1 and smoke/fire detection systems, emulsifiers, fog and fog foam, and dry chemical systems., Classroom Hours: 720 Upon completion of this module, the trainee will be able to describe the three methods of heat transfer, explain the basic principles of exposure protection, identify what piping and fitting materials can be used and where they must be located in an exposure system, explain where water spray systems are typically used, explain the general concepts of using foam as opposed to water as an extinguishing agent, describe the different classes of foam concentrates and foam sprinkler system configurations, explain how to measure density using a refractometer, identify the five basic automatic fire detection methods that can be used for electric release, describe the dangers when working with a carbon dioxide system, and describe the different classes of fire extinguishers and what the rating designations mean. You MUST meet the following requirements before applying for the apprenticeship program. If a candidate has OSHA 10 or CPR credits he/she is encouraged to bring in proof of passing the exams to be evaluated for credit. Upon successful completion of this module, the trainee will be able to identify and describe various types of construction drawings (civil, architectural, structural, mechanical, plumbing/piping, electrical, fire protection); describe the purpose of the five basic components of construction drawings; explain the significance of various drawing elements, such as lines of construction, abbreviations, symbols, and grid lines; identify and describe the use of dimensions, various drawing scales, and how to use engineers and architects scales. The apprentice may incur some costs for tools, books, and materials needed for the trade.
A two-year diploma is not required to qualify for a sprinkler fitter apprenticeship.
Our journeypersons travel from site to site across the Los Angeles area for a non-traditional schedule and change of scenery that'll keep you going for years to come. A High School Diploma or G.E.D.
A sprinkler fitter apprenticeship is a five-year paid program in which apprentices receive both on-the-job practical training and classroom instruction. *Meetings are run by Local 709 Members with group experience and recovery that want to help you. Upon completion of this module, the trainee will be able to explain the basic components and types that make up a fire pump system, identify the NFPA standard hat covers the installation of fire pumps, explain the minimum residual pressure in pounds per square inch (psi) that can be used when pumping from a municipal water supply, convert pressure ratings from psi to feet of head and vice versa, explain how to set and align a pump, discuss he different types of and requirements for fire pump controllers, discuss monitoring requirements for fire for the pumps, describe acceptance testing of fire pumps, perform a mechanical check of a fire pump system, measure the flow of a system, and identify potential causes for a malfunctioning fire pump. A knowledge of tools and experience with mechanical practices found in auto mechanic work or landscaping are beneficial experiences for a sprinkler fitter apprentice candidate. Je gaat hier aan de slag in een Bedrijfsomschrijving:Locatie: regio EmmenJe gaat als Installatiemonteur Sprinkler aan de slag bij een echte specialist in brandbeveiligingstechniek. Bedrijfsomschrijving:Locatie: regio RotterdamDit bedrijf is op zoek naar een collegiale Installatiemonteur Sprinkler. This proctor password requirement is established when you complete the Course Assignment Form after placing your course order. Call us for a quote! The apprenticeship requires 8,000 hours of on-the-job training and a minimum of 160 classroom-training hours each year. Upon completion of this module, the trainee will be able to describe riser check, alarm check valves, and trim, trim an alarm check valve and replace the faceplate gasket, identify and describe flow switches, tamper switches, and pressure switches, install a flow switch and set the retard device, identify and explain fire department connections and hose stations, explain inspectors test connections and auxiliary drains, explain hydrostatic testing and test pumps, perform a hydrostatic test using a pump, describe antifreeze systems, calculate the specific gravity of an antifreeze solution, and complete a contractors material & test certificate, and identify a faulty pressure gauge and replace it. Applications are accepted every other year for a period of 10 days.
Je gaat hier aan de slag in een Bedrijfsomschrijving:Locatie: regio Hilversum Je gaat als Installatiemonteur Sprinkler aan de slag bij een echte specialist in Bedrijfsomschrijving:Locatie: regio VenloAls Installatiemonteur Sprinkler ga je aan de slag bij een organisatie die verantwoordelijk is voor het Jij bent als werkvoorbereider sprinkler het aanspreekpunt voor al het voorbereidend werk rondom de realisatie en oplevering van sprinklerprojecten Heb jij technische kennis van sprinklerinstallaties en ben je de spin in het web? possess a high school diploma or GED equivalency, have reliable transportation to the jobsite and classroom and, be physically able to perform the essential duties of the trade. We educate and train the industry while promoting fire protection systems to save lives and property. Upon completion of this module, the trainee will be able to identify and explain dry-pipe systems and why and where dry pipe systems are used, identify dry-pipe valves and trim, install pressure gauges on an alarm valve, identify and explain air supplies, identify and explain accelerators and exhausters, perform an installation of an accelerator, explain why an exhauster is a quick-opening device and describe possible locations where an exhauster could be installed in a dry pipe system, explain pitching sprinkler piping and auxiliary drains in dry-pipe systems, calculate pitch for dry-pipe systems, identify and explain fire department connections with respect to dry pipe systems, install, set and adjust an air maintenance device, remove and install a faceplate gasket, and reset and troubleshoot a dry-pipe system. The UA has represented hardworking, highly skilled men and women in the plumbing and pipe fitting industry for over 125 years. Upon successful completion of this module, the trainee will be able to identify and explain how to use various types of power drills and impact wrenches (power drills, bits, hammer drill, pneumatic drill); identify and explain how to use various types of power saws (circular, saber, reciprocating, portable band, miter, cutoff); identify and explain how to use various grinders and grinder attachments; and identify and explain how to use miscellaneous power tools such as pneumatic and powder-actuated fastening tools, pavement breakers, and hydraulic jacks. Upon completion of this module, the trainee will be able to follow basic safety precautions for the preparation and installation of steel pipe, identify types of steel pipe, calculate take-outs, set up equipment, measure and cut steel pipe, assemble threaded, grooved, and plain-end pipe, and check for correctness of end preparation. High school students preparing to become a sprinkler fitter should seek out part-time jobs that require being physically fit and outdoors in a variety of conditions.
Dit Bedrijfsomschrijving:Locatie: regio BredaJe gaat als Leerling Monteur Sprinkler aan de slag bij een echte specialist in brandbeveiligingstechniek. No other organization serves the training needs of the Sprinkler Fitting industry like the United Association. (G0)Upon completion of Level I the trainee will be awarded 15.25 CEUs (152.5 Credit Hours). We can help you explore your interests and find a career you love.Visit us online or stop by a campus. A Birth Certificate, or Baptismal Record or California Drivers License for proof of age (18 & older only). Megan Ringwelski, in her fourth year of training with Sprinklerfitters Local 417, was named Apprentice of the Year.
Our organization is here to support and protect the careers and interests of our members, whether you're an apprentice or a retiree! Upon completion of this module, the trainee will be able to recognize federal, state, and jurisdictional requirements for supply and disposal of fire sprinkler system water, identify different water supplies for automatic sprinkler systems, explain the three qualities that are critical to the water supply for fire sprinkler systems, identify types of water storage and explain their usage, describe different water main configurations, perform flow test procedures, plot residual and static pressure on a graph, read a flow test results sheet and determine the number of outlets flowed, hydrant outlet size, and static and residual pressure, fill out a flow test summary sheet, identify and describe backflow preventers and methods of installation, and identify and describe meters used in fire sprinkler systems.
Excellent pay, benefits and job security. Years to Complete: 4-5 HCC Campus: Dale Mabry and Plant City. Upon completion of this module, the trainee will be able to identify types and properties of soil, explain excavation safety, explain sloping requirements for different types of soil, explain digging trenches, describe excavation support systems, describe types of bedding material, identify and describe types of underground pipe, describe thrust blocks and restraints, identify and describe hydrants, yard valves, hydrant houses, and associated appurtenances, explain testing, inspection, and chlorinating of underground pipe, and fill out an Underground Test Certificate.
Responsibilities include unloading and installing allpiping and tubing apparatus and equipment such as:, The technologies in this industry also include CO2, Cardox1 and smoke/fire detection systems, emulsifiers, fog and fog foam, and dry chemical systems., Classroom Hours: 720 Upon completion of this module, the trainee will be able to describe the three methods of heat transfer, explain the basic principles of exposure protection, identify what piping and fitting materials can be used and where they must be located in an exposure system, explain where water spray systems are typically used, explain the general concepts of using foam as opposed to water as an extinguishing agent, describe the different classes of foam concentrates and foam sprinkler system configurations, explain how to measure density using a refractometer, identify the five basic automatic fire detection methods that can be used for electric release, describe the dangers when working with a carbon dioxide system, and describe the different classes of fire extinguishers and what the rating designations mean. You MUST meet the following requirements before applying for the apprenticeship program. If a candidate has OSHA 10 or CPR credits he/she is encouraged to bring in proof of passing the exams to be evaluated for credit. Upon successful completion of this module, the trainee will be able to identify and describe various types of construction drawings (civil, architectural, structural, mechanical, plumbing/piping, electrical, fire protection); describe the purpose of the five basic components of construction drawings; explain the significance of various drawing elements, such as lines of construction, abbreviations, symbols, and grid lines; identify and describe the use of dimensions, various drawing scales, and how to use engineers and architects scales. The apprentice may incur some costs for tools, books, and materials needed for the trade.
A two-year diploma is not required to qualify for a sprinkler fitter apprenticeship.
Our journeypersons travel from site to site across the Los Angeles area for a non-traditional schedule and change of scenery that'll keep you going for years to come. A High School Diploma or G.E.D.
A sprinkler fitter apprenticeship is a five-year paid program in which apprentices receive both on-the-job practical training and classroom instruction. *Meetings are run by Local 709 Members with group experience and recovery that want to help you. Upon completion of this module, the trainee will be able to explain the basic components and types that make up a fire pump system, identify the NFPA standard hat covers the installation of fire pumps, explain the minimum residual pressure in pounds per square inch (psi) that can be used when pumping from a municipal water supply, convert pressure ratings from psi to feet of head and vice versa, explain how to set and align a pump, discuss he different types of and requirements for fire pump controllers, discuss monitoring requirements for fire for the pumps, describe acceptance testing of fire pumps, perform a mechanical check of a fire pump system, measure the flow of a system, and identify potential causes for a malfunctioning fire pump. A knowledge of tools and experience with mechanical practices found in auto mechanic work or landscaping are beneficial experiences for a sprinkler fitter apprentice candidate. Je gaat hier aan de slag in een Bedrijfsomschrijving:Locatie: regio EmmenJe gaat als Installatiemonteur Sprinkler aan de slag bij een echte specialist in brandbeveiligingstechniek. Bedrijfsomschrijving:Locatie: regio RotterdamDit bedrijf is op zoek naar een collegiale Installatiemonteur Sprinkler. This proctor password requirement is established when you complete the Course Assignment Form after placing your course order. Call us for a quote! The apprenticeship requires 8,000 hours of on-the-job training and a minimum of 160 classroom-training hours each year. Upon completion of this module, the trainee will be able to describe riser check, alarm check valves, and trim, trim an alarm check valve and replace the faceplate gasket, identify and describe flow switches, tamper switches, and pressure switches, install a flow switch and set the retard device, identify and explain fire department connections and hose stations, explain inspectors test connections and auxiliary drains, explain hydrostatic testing and test pumps, perform a hydrostatic test using a pump, describe antifreeze systems, calculate the specific gravity of an antifreeze solution, and complete a contractors material & test certificate, and identify a faulty pressure gauge and replace it. Applications are accepted every other year for a period of 10 days.
Je gaat hier aan de slag in een Bedrijfsomschrijving:Locatie: regio Hilversum Je gaat als Installatiemonteur Sprinkler aan de slag bij een echte specialist in Bedrijfsomschrijving:Locatie: regio VenloAls Installatiemonteur Sprinkler ga je aan de slag bij een organisatie die verantwoordelijk is voor het Jij bent als werkvoorbereider sprinkler het aanspreekpunt voor al het voorbereidend werk rondom de realisatie en oplevering van sprinklerprojecten Heb jij technische kennis van sprinklerinstallaties en ben je de spin in het web? possess a high school diploma or GED equivalency, have reliable transportation to the jobsite and classroom and, be physically able to perform the essential duties of the trade. We educate and train the industry while promoting fire protection systems to save lives and property. Upon completion of this module, the trainee will be able to identify and explain dry-pipe systems and why and where dry pipe systems are used, identify dry-pipe valves and trim, install pressure gauges on an alarm valve, identify and explain air supplies, identify and explain accelerators and exhausters, perform an installation of an accelerator, explain why an exhauster is a quick-opening device and describe possible locations where an exhauster could be installed in a dry pipe system, explain pitching sprinkler piping and auxiliary drains in dry-pipe systems, calculate pitch for dry-pipe systems, identify and explain fire department connections with respect to dry pipe systems, install, set and adjust an air maintenance device, remove and install a faceplate gasket, and reset and troubleshoot a dry-pipe system. The UA has represented hardworking, highly skilled men and women in the plumbing and pipe fitting industry for over 125 years. Upon successful completion of this module, the trainee will be able to identify and explain how to use various types of power drills and impact wrenches (power drills, bits, hammer drill, pneumatic drill); identify and explain how to use various types of power saws (circular, saber, reciprocating, portable band, miter, cutoff); identify and explain how to use various grinders and grinder attachments; and identify and explain how to use miscellaneous power tools such as pneumatic and powder-actuated fastening tools, pavement breakers, and hydraulic jacks. Upon completion of this module, the trainee will be able to follow basic safety precautions for the preparation and installation of steel pipe, identify types of steel pipe, calculate take-outs, set up equipment, measure and cut steel pipe, assemble threaded, grooved, and plain-end pipe, and check for correctness of end preparation. High school students preparing to become a sprinkler fitter should seek out part-time jobs that require being physically fit and outdoors in a variety of conditions.
Dit Bedrijfsomschrijving:Locatie: regio BredaJe gaat als Leerling Monteur Sprinkler aan de slag bij een echte specialist in brandbeveiligingstechniek. No other organization serves the training needs of the Sprinkler Fitting industry like the United Association. (G0)Upon completion of Level I the trainee will be awarded 15.25 CEUs (152.5 Credit Hours). We can help you explore your interests and find a career you love.Visit us online or stop by a campus. A Birth Certificate, or Baptismal Record or California Drivers License for proof of age (18 & older only). Megan Ringwelski, in her fourth year of training with Sprinklerfitters Local 417, was named Apprentice of the Year.
Our organization is here to support and protect the careers and interests of our members, whether you're an apprentice or a retiree! Upon completion of this module, the trainee will be able to recognize federal, state, and jurisdictional requirements for supply and disposal of fire sprinkler system water, identify different water supplies for automatic sprinkler systems, explain the three qualities that are critical to the water supply for fire sprinkler systems, identify types of water storage and explain their usage, describe different water main configurations, perform flow test procedures, plot residual and static pressure on a graph, read a flow test results sheet and determine the number of outlets flowed, hydrant outlet size, and static and residual pressure, fill out a flow test summary sheet, identify and describe backflow preventers and methods of installation, and identify and describe meters used in fire sprinkler systems.