THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of animplied warranty, so the above limitations or exclusions may not apply to You. 2. Install sanitary well seal on top of well casing; use steel nipple through Drive Pipe well seal as shown in Figure 2. Replace foot valve. frequently Venturi, nozzle or impeller is clogged Clean venturi, nozzle or impeller. NOTICE: Fill pipe with water as each length is added to be sure foot valve and connections do not leak. Control Regulator Do not increase pipe size by stages. Youmust pay all labor and shipping charges associated with this warranty and must request warranty service through the installingdealer as soon as a problem is discovered. Be sure to prime pump before starting. (**) Pressure Gauge sold separately, not included with J212-19E, see Page 14. Pump cycles too frequently See section below on too frequent cycling. If receding water level ip sluing and see if water priming hole). 2. Leave room to use wrenches.Foot Valve & Strainer Foot Valve & Strainer Plug 1 drive port when installing on shallow well. Consult your local building inspector for code information. does not shut off or contacts are welded together pump cycles too Faucets have been left open Close faucets. pump submersible install well water casing case steel lowering tricks lesson follow burr grinder sharp remove using AVC Tubing Up to 100 ft run: Same size as pump discharge port. The supply voltage must be within 10% of the motor nameplate voltage. SSJC SSJD SSJE No. Keep work area clean, uncluttered and properly lighted;Replace missing or damaged safety labels. Water pressure in the casing will then soak the cup seals. IMPORTANT: Align locating lugs on adapter flange and pump base so that Suction pump discharge aligns with piping. ), OWNERS MANUAL Vertical Jet Pumps - STA-RITE. Reinstall the Motor end cover. Air leaks 2. Remove pressure gauge to vent pump; drain pressure tank and all piping to a point below frost line. Move the voltage change plug to the 115 volt the dial window as shown in Figure 10. position. See Electric al section of this manual and Hazardous pressure! Once unit has primed and pressure stabilized, slowly open (turn 20 80 counterclockwise - Figure 15) regulator valve until pressure falters (pressure gauge needle flutters; pump may become noisy - see Figure 100 16). Fill pump with water before starting.Figure 11: Close Regulator 2361a 0697 NEVER run pump against closed disc harge, to do so canFigure 12: Fill Pump 2360a 0697 boil water inside pump, causing hazardous pressure in unit and possibly scalding persons handling pump. This type of well must be vented to the outside of any enclosure. To avoid burnsignored. With ejector set, install well casing adapter. If in doubt, consult a qualified warns about hazards that will cause serious electrician.personal injury, death or major property damage ifignored. 2. 100 ft. to 300 ft run: Increase one pipe size. Table of Contents 3Thank you for purchasing a top quality, factory tested pump. Use a solid copper wire at least as large as the power supply wires. pumps pump water hand motors A-OFFSET INSTALLATION IthMaPnOthRB-eTOAVflENoRSwTTTEH:oEEYLuWoPtEuIPtLhrELrwISNoHSeuOTlgWAlhLNmLpAuTusIOmt Nbpe! Disconnect power before working on pump or motor. Any water in AVC will then drain back into tank (see Figure 18). Re-prime according to instructions. Pull the voltage change plug off of the tabs. shock hazard, use 3. Installation 5 7. WIRINGCONNECTIONS Fire hazard. Read instructions and handle the seal with care. If increasing discharge pipe size, install reducer in pump discharge port. 5. Use PTFE pipe thread sealant tape tape on male threads. At this point, close (turn clockwise) regulator valve slightly until pressure stabilizes. 5. 11. Piping to the screwdriver to short capacitor terminals well need not be disturbed. IMPORTANT: Check motor label for lubrication instructions. Be sure disconnect switch is off. Leak in suction side of pump Suction pipe is sucking air.

Align locating lugs on pump base with lugs on adapter flange; attach Leathers pump to flange with cap screws provided. (Ask your well driller for this information. No dealers found. Lower suction line into water and re-prime. Follow steps 1a, b, c under Winterizing, above. Apply gasket to adapter Ejector flange, making sure that holes line up. warns about hazards that will or can causeminor personal injury or property damage if ignored. Connection Procedure: 1. 4. Do not ground to a gas supply line. base plate foundation anchor bolt screw levelling pump leveling plates installation pumps centrifugal baseplate steel washer sleeved grout chock between Make sure foot valve operates freely: attach to ejector with a close nipple. insulated-handle 4. Pentair Flotec FP4432-01 1 HP Vertical Deep Well Jet Pump, 260' for 4" or larger well / 180' for 2" well, Undersink & Countertop Filtration Systems, Residential Softening & Filtration Valves, Recreational Vehicle Plumbing Accessories, Turf Management & Pest Control Accessories, Water Treatment Solutions for Drinking Water, Water Treatment Solutions for Office Water & Coffee, Water Treatment Solutions for Warewashing, Residential Filtration Solutions Customer Service, Commercial Filtration Solutions Customer Service, Adjusting Well Pump Pressure Switches Instructions, Pentair Medical Carrier Transparency Reports, Do Not Sell My Personal Information - CA Residents Only, Superior performance at depths to water of 50' or more, Rugged, heavy-duty cast iron pump housing, Ready-to-install 230 volt motor - see manual for 115 volt conversion. system before working on any component.Hazardous voltage. 14. Remove paper backing from adhesive gasket. Foot Valve & Strainer 4. In offset installations, pump suction port should be highest point in suction pipe; there should be no sags in suction pipe (run it straight and at a slight angle upward from well head to pump).ON OFF 1060 0697Figure 13: Start Pump Pre-Charged STANDARD TANK CONNECTION Pressure Tank When a standard tank is used, an air volume control (AVC) adds air to the 40 60 tank when it is needed. 40 60 6. After unscrewing the impeller, carefully remove the rotating part of the seal by prying up on the sealing washer using two screwdrivers (Figure 20). 1. overload kicks off Voltage is too low Check with power company. To avoid electrical 2. Install heavier wiring if wire size is too small (See Electrical / Wiring Chart). 1 Adjusting Screw, 1/4x20x3/4 U30-537ZP 1 2 Spring Follower 3 Diaphragm J24-7 1 4 Valve Guide 5 Diaphragm and Valve Guide Assembly J20-5 1 6 Valve Seat Only 7 Regulator Body with Valve Seat J42-4 1 8 1/2x1/8 NPT Reducer Bushing 9 Pressure Gauge** J120-14 1 10 Adjusting Screw 11 10-32x1/2 Machine Screws J66-15 1 12 Regular Bonnet 13 Spring Button J112-8E 1 14 Spring * 1 U239-3 1 J28D 1 * 6 J52-5ZZ 1 J48 1 J24-9 (*) Standard hardware item, available locally. If possible, connect the pump to a separate branch circuit with no other appliances on it. 6. Pipe 10. To do so will void warranty.The label NOTICE indicates special instructions whichare important but not related to hazards. INSTALLATION OF NEW SEAL 1. Check locally for frost protection requirements (usually pipe must be 12 below frost line and pump must1-1/4\" Plastic Suction PipeSpecial 1-1/4\" Plastic Pipe be insulated). Pump body may explode if used as aCalifornia Proposition 65 Warning booster pump unless relief valve capable of passing full pump flow at 75 psi is installed. This warranty gives You specific legal rights andYou may also have other rights which vary from state to state.This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011. Add lengths of pipe until the ejector reaches the proper depth. In such cases, a pre-charged tank (which needs no air control) is recom mended. Install, ground, wire, and maintain your pump in compliance with the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), as applicable, and with all local codes and ordinances that apply. Replace foot valve or check valve. If there are other wires, they should be capped. To change to 115 volts:1. Freezing will split pipe, damage pump and void1t\"hDerivewPaipreranty. Well Seal 300 ft. to 600 ft run: Increase two pipe sizes.Figure 4: Pump With Standard Tank2355b 0697 PRESSURE TANK INSTALLATION DEEP WELL The Pressure Tank provides a reservoir of water under pressure and maintains cushion of air pressure to prevent pipe hammering and possible damage to plumbing components. Standard Tank: a. 2. Keep one on hand for future use. Do not touch metal screwdriver blade or capacitor terminals. Check AVC for defects. Do not alter the wiring in single voltage motors. limed, causing excess friction Piping is too small in size Use larger piping. Unions installed near pump and well will aid in servicing. Water level below suction pipe inlet 2. To change to 115 volts: Voltage is factory set to 230 volts. Since the gases rise in the well casing, the waterFigure 22: Protect Seal Faces 1072 0697 sucked down through the pipe and into the suction pump is free of gas. Clean face of sealing washer with clean cloth. 3. Close regulator valve (turn clockwise - see Figure 11). buried in sand or mud Clean foot valve and strainer. Packed well point Backflush well point or sink new point. Like this book? From residential and business solutions that help people move, improve and enjoy their water, to our sustainable industrial applications, Pentair makes the most of life's essential resources. Never wire a 115 volt motor to a 230 volt line.Plug Type Voltage Selector Dial Type Voltage Selector Power Supply Connections Voltage Change Dial Pressure Switch Ground Wire ConnectionFigure 7: Voltage set to 230 volts, Plug Type Figure 9: Voltage set to 230 volts, Dial TypeVoltage is factory set to 230 volts. Dismantle pump: Remove canopy, and by holding the centrifugalFigure 19: Hold Shaft to Unscrew switch with a wrench, the impeller can be unscrewed off the pumpImpeller shaft, exposing the seal (Figure 19). 1.

This setting provides maximum flow (Figure 17). IMPORTANT: Your pump pressure switch is set for a 20-40 PSI range andFigure 5: Pump With Pre-charged Tank2358b 0697 requires a tank pre-charge of 28 PSI for proper operation (see Figure 6). (Supplied with Ejector) Be sure all pipes and foot valve are clean and in good condition.1\" Plastic Pipe Adapter Remove air pockets in suction pipe.Ejector Assembly Make sure there are no leaks in the suction pipe. Check air valve for leaks (use soapy solution) and replace core if necessary. 20 80 With faucets open, pressure will drop until pump starts; with faucets closed, pressure will build up until pump shuts off. serves as 9. SINGLE PIPE EJECTOR INSTALLATION Single pipe installations require (see Figure 3): a. Galvanized steel pipe b. Leather packer-type ejector with built-in foot valve c. Turned couplings (supplied with packer-type ejector) d. Well casing adapter. Please try another location. NOTICE: Open water system faucets before priming pump for the first time. Remove rubber seat ring. Pry loose the floating seat by applying screwdriver between seat and cavity in casting. If the pressure switch is not connected to the motor, connect the green ground screw in the switch to the green ground screw under the motor end cover. Pump only water with this pump.Carefully read and follow all safety instructions in this Periodically inspect pump and system components.manual and on pump. 2. L1L1 The highly polished and lapped faces of the seal are easily 174 0697 damaged. * (Notice: Stop 3. Ejector or impeller is plugged Clean foot valve or strainer. deliver water to full estimated capacity Steel piping (if used) is corroded or Replace with plastic pipe where possible, otherwise with new steel pipe. Pressure switch contacts are dirty DISCONNECT POWER and file contacts with emery board or nail file. 5. This warranty is not transferable.STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULARPURPOSE. 6. a. Check system by alternately opening and closing faucets in the system. Find out where to purchase online or in a retail location near you. OWNERS MANUAL Vertical Jet Pumps 2875 0697ASB SSJ Series Installation/Operation/PartsFor further operating, installation, or maintenance assistance: Call 1-888-782-7483293 WRIGHT STREET, DELAVAN, WI 53115 WWW.sta-rite.COM S724 (REV 01/14/13)PH: 888-782-7483 2013 Pentair Ltd. All Rights Reserved. Check all connections on suction line, AVC, and ejector with soapy water or shaving cream. No request for service will be accepted if received after the Warranty Period hasexpired. U nscrew priming 2. Motor runs but no Pump in new installation did In new installation: water is delivered* not pick up prime through: 1. Check Standard pressure tank is waterlogged all connections for air leaks. Attach the incoming power leads to the two outer screws on the pressure switch as shown in Figure 7. screws on the pressure switch as shown in Figure 9.5. Make sure all joints are tight. 1. Maintenance 11 LL22 Pump DISAssembly BB The seal consists primarily of two parts: a rotating member and a floating AA seat. base volute. Check all connections on suction line and shaft seal. Fill pump and suction pipe with water (Figure 12). Thread adapter flange onto Venturi suction pipe from well and align nipple and drive pipe. 1 Motor Canopy J18-59 J18-59 J18-59 1 2 Motor A200CH A200DH A200EH 1 3 Adapter L2-8B L2-8B L2-8B 1 4 3/8-16x1 Capscrews U30-74ZP U30-74ZP U30-74ZP 2 5 Shaft seal U109-6A U109-6A U109-6A 1 6 1/4 NPT Barbed Elbow U111-212T U111-212T U111-212T 1 7 Pressure Regulator (See Page 13) J212-19E J212-19E J212-19E 1 7A Pressure Gauge U239-3 U239-3 U239-3 1 8 5/16-18x5/8 Capscrews U30-58ZP U30-58ZP U30-58ZP 6 9 1 NPTx2 Nipple U37-55GPT U37-55GPT U37-55GPT 1 10 Tube U37-672P U37-672P U37-672P 1 11 1/4 NPT Barbed Fitting U111-211T U111-211T U111-211T 1 12 Pressure Switch U217-1215 U217-1215 U217-1215 1 13 1/2 Locknut U36-112ZP U36-112ZP U36-112ZP 1 14 Connector J43-13C J43-13C J43-13C 1 15 Impeller J105-42P J105-8PN J105-22P 1 16 Wear Ring J8 J8A J8A 1 17 Gasket J20-9 J20-9 J20-9 1 18 Volute with Wear Ring J101-35B J101-35 J101-35 1 19 1/4 NPT Pipe Plug U78-941ZPV U78-941ZPV U78-941ZPV 1 20 Base Volute Assembly (Includes Key Nos. Use two clamps perbetween adapter or moreand pump flange) joint to prevent air leaks into suction pipe. Operation 9 40 60 PRIMING THE PUMP 20 80 NEVER run pump dry. Gases rise to surface Ejector Pipe strap or wire to hold pipe sleeve Tail pipe Foot valve Pipe sleeve Pipe capFigure 23: Gas/Air Control in Well 2876 0697 Connect the power supply wires to the pressure switch as shown in Figure 7. General Safety warns about hazards that can cause serious Do not touch an operating motor. The motor shaft has right hand threads.Figure 20 1067b 0697 Removal of Old Seal 1. See tank owners manual. AIR CONTROL IN FLOWING WELLS Flowing wells or wells with little or no drawdown, could create a special problem in air control in the operation of your standard tank system.